GCV-40-385-1+1-FM Single-Phase AC Power Surge Protective Device, Class II, 40kA Imax
Request a quote
Quality & certifications
Description
The GCV-40-385-1+1-FM is a Class II surge protective device (SPD) designed for single-phase AC power systems. It limits transient overvoltages at the L-N and N-PE paths, with a nominal discharge current In of 20kA and a maximum discharge current Imax of 40kA under the 8/20µs waveform. The device is intended for use as second-stage (Class C) surge protection for load equipment in power distribution systems.
Product Overview
The GCV-40-385-1+1-FM is a single-phase AC power surge protective device classified as Class II. It is designed to be installed in LPZ1 zones or directly inside distribution cabinets (switch boxes). The SPD connects in parallel to the power line and provides protection across L-N and N-PE paths. A status indicator window shows green during normal operation and red when the device has failed. An optional remote signaling contact provides a changeover contact (NC-COM-NO) for alarm monitoring.
Key Features
- Class II surge protective device for single-phase AC power systems
- Nominal discharge current In: 20kA (8/20µs)
- Maximum discharge current Imax: 40kA (8/20µs)
- L-N voltage protection level Up: 1.8kV at In
- N-PE voltage protection level Up: 1.0kV at In
- L-N response time tA: ≤25ns
- N-PE response time tA: ≤100ns
- Status indicator: green for normal, red for failure
- Optional remote signaling contact: NC-COM-NO changeover contact
- 35mm electrical DIN rail mounting
- IP20 enclosure protection
Technical Specifications
| Parameter | Value |
|---|---|
| Model | GCV-40/385/1+1 FM |
| SPD classification | II |
| Nominal operating voltage Un | 220V~ |
| L-N maximum continuous operating voltage Uc | 385V~ |
| N-PE maximum continuous operating voltage Uc | 255V~ |
| Nominal discharge current In (8/20µs) | 20kA |
| Maximum discharge current Imax (8/20µs) | 40kA |
| L-N voltage protection level Up (In@8/20µs) | 1.8kV |
| N-PE voltage protection level Up (In@8/20µs) | 1.0kV |
| L-N response time tA | ≤25ns |
| N-PE response time tA | ≤100ns |
| L-N, N-PE status indication | Green: normal / Red: failed |
| Remote signaling contact type | Changeover contact, NC-COM-NO; NC-COM normally closed, NO-COM normally open |
| Remote signaling contact AC rating | 250V/0.5A |
| Remote signaling contact DC rating | 125V/0.2A |
| Installation method | 35mm DIN rail |
| Conductor connection capacity | ≤25mm² |
| Maximum torque | 3.2Nm~3.7Nm |
| Enclosure material | PC+PBT |
| Enclosure material flame rating | UL94-V0 |
| Enclosure protection rating | IP20 |
| Temperature and humidity range | -40℃ to +80℃, relative humidity ≤95% |
| Altitude | ≤3000m |
| Main body dimensions | 90mm × 65mm × 36mm (tolerance ±1mm) |
Applications
The GCV-40-385-1+1-FM is used for second-stage (Class C) lightning and surge protection of load equipment in single-phase AC power systems. It can be installed in LPZ1 zones or directly in distribution cabinets (switch boxes). Typical applications include protection of electronic equipment downstream of the main distribution point in single-phase power installations.
Installation and Use
- The SPD can be installed in LPZ1 zones or directly inside distribution cabinets (switch boxes).
- Mount the device on a 35mm electrical DIN rail.
- Connect the SPD in parallel to the power line. “L/+” connects to the phase line or positive line; “N/-” connects to the neutral line or negative line.
- Use multi-core copper conductors of 10-25mm² for connection. When using direct parallel connection, keep the total wiring length within 0.5m for better protection effect.
- Install a suitable air circuit breaker or fuse upstream of the SPD. Use a circuit breaker with C trip characteristic.
- Disconnect power before installation. Live operation is strictly prohibited. Connecting conductors must meet the requirements.
- Connect the ground terminal to earth with the shortest possible conductor. The grounding connection must be well bonded to earth.
- Keep the protected line at a sufficient safe distance from the incoming line and ground line to avoid secondary induction effects.
- During normal operation, the status indicator window is green. When the SPD has failed, the indicator turns red.
- The SPD requires no special maintenance; perform regular checks for module looseness and status indication.
- Replace the SPD if the status indicator turns red or if the alarm dry contact becomes open circuit.
Frequently Asked Questions
What does the status indicator mean?
Green indicates normal operation. Red indicates the SPD has failed and needs repair or replacement.
What is the maximum discharge current of this SPD?
The maximum discharge current Imax is 40kA under the 8/20µs waveform.
What conductor size is recommended for connection?
Use multi-core copper conductors of 10-25mm². The conductor connection capacity is ≤25mm².
How is the SPD mounted?
The device mounts on a 35mm electrical DIN rail and connects in parallel to the power line.
Related products
-

GCV-60/385/1+1 Single-Phase AC Power Surge Protective Device, Class II, 60kA Imax
Request a quote -

GBV-120-385-3+1 FM AC Power Surge Protective Device, Class II, 3+1 Configuration
Request a quote -

GBV-100-385-1+1-FM Single-Phase AC Power Surge Protective Device, Class II, 100 kA Imax
Request a quote -

G1V-40-385-FM Three-Phase AC Power Surge Protective Device, Class II, 40kA Imax, Hot-Swappable
Request a quote