GCV-40-275-2 AC Power Surge Protective Device, 2-Pole, 275V Uc, 40kA Imax
Request a quote
Quality & certifications
Description
The GCV-40-275-2 is a 2-pole AC power surge protective device in the GCV-40 series. It is designed for second-level (Class C) lightning protection and surge protection of load equipment in power systems. The device limits transient overvoltages on the protected circuit and provides a local status indication through a green/red window.
Product Overview
The GCV-40 series is used for second-level (Class C) lightning protection and surge protection of load equipment in power systems. The GCV-40-275-2 variant is the 2-pole configuration with a maximum continuous operating voltage Uc of 275V. It is intended for parallel connection to the power line and is suitable for installation in LPZ1 zones or directly inside distribution cabinets (switch boxes).
Key Features
- 2-pole AC power surge protective device
- Maximum continuous operating voltage Uc: 275V
- Nominal discharge current In: 20kA (8/20μs)
- Maximum discharge current Imax: 40kA (8/20μs)
- Voltage protection level Up at In: 1.35kV
- Response time tA (L/N-PE): ≤25ns
- Failure indication: green = normal, red = failed
- Backup fuse: 32Agl/gG
- 35mm electrical DIN rail mounting
- IP20 enclosure protection
Technical Specifications
| Parameter | Value |
|---|---|
| Model | GCV-40/275/2 |
| Maximum continuous operating voltage Uc | 275V |
| Nominal discharge current (8/20μs) In | 20kA |
| Maximum discharge current (8/20μs) Imax | 40kA |
| Voltage protection level (In) Up | 1.35kV |
| Response time tA (L/N-PE) | ≤25ns |
| N-PE maximum continuous operating voltage Uc | / |
| N-PE voltage protection level (In) Up | / |
| Failure indication | Green: normal; red: failed |
| Backup fuse | 32Agl/gG |
| Temperature range | -40°C…+80°C |
| Installation wiring method / specification | Parallel / stranded 10-35mm² |
| Housing material | Reinforced thermoplastic, UL94-V0 |
| Product dimensions | 91 × 65.5 × 36 mm |
| Mounting method | 35mm electrical DIN rail |
| Protection rating | IP20 |
Applications
The GCV-40-275-2 is used for second-level (Class C) lightning protection and surge protection of load equipment in power systems. It can be installed in LPZ1 zones or directly in distribution cabinets (switch boxes).
Installation and Use
- Before installation, inspect the surge protective device. Do not install it if any defect is present.
- Use the device only within the conditions specified in the technical table. Exceeding the given upper limits may damage the surge protective device or the protected equipment.
- Installation must follow the relevant standards and specifications for the protector. The device must be installed by qualified personnel with relevant certification in front of the electronic equipment to be protected.
- The GCV-40 series can be installed in LPZ1 zones or directly in distribution cabinets (switch boxes).
- The device can be fixed on a 35mm electrical DIN rail.
- Connect the surge protective device in parallel to the power line. “L/+” connects to the power phase line or positive line; “N/-” connects to the power neutral line or negative line. The copper conductor cross-section at both ends of the surge protective device is 10-35mm².
- For a surge protective device installed on a circuit, an overcurrent protection device such as an air switch or fuse must be installed at its front end.
- Connect the surge protective device to ground using the shortest possible line. Grounding is by terminal connection; the ground line must be connected to the lightning protection ground line.
- The protected line should maintain sufficient safety distance from the incoming line and ground line to avoid secondary induction on the line.
- Under conditions not exceeding the requirements, installation does not require long-term maintenance; only routine system maintenance is needed. If the green indicator window turns red during use, the surge protective device is damaged and must be repaired or replaced.
Frequently Asked Questions
What does the status window indicate?
Green indicates normal operation; red indicates that the device has failed and needs repair or replacement.
How is the GCV-40-275-2 connected?
It is connected in parallel to the power line. “L/+” connects to the phase or positive line, and “N/-” connects to the neutral or negative line. The ground terminal must be connected to the lightning protection ground line.
What conductor size is used for connection?
The connecting copper conductors at both ends of the device use a stranded cross-section of 10-35mm².
What backup fuse is specified?
The specified backup fuse is 32Agl/gG.
Related products
-

G1V-40-385-FM Three-Phase AC Power Surge Protective Device, Class II, 40kA Imax, Hot-Swappable
Request a quote -

GBV-120-385-3+1 FM AC Power Surge Protective Device, Class II, 3+1 Configuration
Request a quote -

GBV-80-385-1+1 FM Single-Phase AC Power Surge Protective Device, Class II, 80kA Imax
Request a quote -

GBV-100-385-3+1-FM Three-Phase AC Power SPD, Class II, 100kA Imax, 3+1 Configuration with Remote Signaling
Request a quote