PDU-AC220V-40A2P-16GB10A+8GB16A Rack Power Distribution Unit, 16× GB10A + 8× GB16A Anti-Loosening Outlets, Single-Phase 40A
Request a quote
Description
The PDU-AC220V-40A2P-16GB10A+8GB16A is a single-phase rack power distribution unit rated AC220V 40A. It distributes power to 16 GB10A outlets and 8 GB16A anti-loosening outlets, giving a total outlet combination of 16+8. Input is single-phase via a terminal box, with cable entry at the top of the unit.
Product Overview
The unit is built around copper busbar internal connections of 3.0 mm diameter and is housed in a black RAL9005 aluminum-alloy enclosure. It is mounted vertically on the left side using brackets, intended for the rear of a cabinet. A circuit breaker provides protection and monitoring, and a hot-swap indicator lamp provides control indication.
Key Features
- Single-phase AC220V 40A input through a terminal box
- 16 GB10A outlets plus 8 GB16A anti-loosening outlets (16+8 combination)
- Copper busbar internal connections, 3.0 mm diameter
- Schneider 40A/1P circuit breaker
- Hot-swap indicator lamp
- Black RAL9005 aluminum-alloy housing
- Vertical left-side bracket mounting for the rear of a cabinet
- Top cable entry with PG21 cable fixing
Technical Specifications
| Parameter | Value |
|---|---|
| Product code | 10300412 |
| Product model | GDE-40A1Px2-Lgt-16GB10A+8GB16A-FT-A |
| Customer product model | PDU-AC220V-40A2P-16GB10A+8GB16A(A) |
| Product code (factory) | 051601501388 |
| Warranty period | 3 years |
| Outlet type and quantity | 16 × GB10A + 8 × GB16A anti-loosening |
| Outlet combination | 16+8 |
| Internal connection | Copper busbar connection (diameter 3.0 mm) |
| Power input method | Single-phase input – terminal box |
| Cable plug type | / |
| Input connectable conductor capacity | 3 × 10 mm² |
| Cable installation method | Top entry |
| Cable fixing | PG21 |
| Housing color | Black RAL9005 |
| Dimensions (L × W × H) | 1726 × 60 × 44 mm; tolerance: (L) ± 4 mm, (W/H) ± 2 mm |
| Mounting hole center distance | 1694 mm |
| Aluminum-alloy housing length | 1651 mm |
| Product mounting method | Bracket mounting |
| Bracket mounting direction | Vertical left mounting (rear of cabinet) |
| Control indication function | Hot-swap indicator lamp |
| Protection and monitoring function | Circuit breaker |
| Circuit breaker brand | Schneider 40A/1P |
| Screw torque – M3 | 0.6 N·m / 6 kgf·cm |
| Screw torque – M4 | 1.6 N·m / 16.3 kgf·cm |
| Screw torque – M5 | 3 N·m / 30.5 kgf·cm |
| Screw torque – M6 | 5 N·m / 51 kgf·cm |
| Screw torque – M8 | 11 N·m / 112 kgf·cm |
| Factory accessories | M6×12 screws and M6 floating square nuts, 4 pcs each; manual (including certificate of conformity) 1 pcs |
| Product identification – model | GDE-40A1P |
| Product identification – input | AC220V 40A |
| Product identification – output | 16 × GB10A + 8 × GB16A anti-loosening |
Applications
The unit is intended for rack power distribution in cabinets, mounted vertically on the left side at the rear of the cabinet. The combination of GB10A and GB16A anti-loosening outlets supports distribution to equipment requiring these outlet types within a single-phase AC220V 40A supply.
Installation and Use
Install the unit using the supplied brackets in the vertical left orientation at the rear of the cabinet. The mounting hole center distance is 1694 mm. Cable entry is at the top of the unit, and the cable is fixed with a PG21 gland. The input accepts conductors of 3 × 10 mm² connected through the terminal box.
Tighten fasteners to the specified torque: M3 at 0.6 N·m (6 kgf·cm), M4 at 1.6 N·m (16.3 kgf·cm), M5 at 3 N·m (30.5 kgf·cm), M6 at 5 N·m (51 kgf·cm), and M8 at 11 N·m (112 kgf·cm). The stated torque tolerance is ±10%. Factory accessories include M6×12 screws and M6 floating square nuts, 4 pcs each, plus one manual containing the certificate of conformity.
Frequently Asked Questions
What outlets does this PDU provide?
It provides 16 GB10A outlets and 8 GB16A anti-loosening outlets, a 16+8 combination.
What is the input rating and connection method?
The input is single-phase AC220V 40A, connected through a terminal box with top cable entry and PG21 cable fixing. The input accepts 3 × 10 mm² conductors.
How is the unit mounted?
It is bracket-mounted vertically on the left side, intended for the rear of a cabinet, with a mounting hole center distance of 1694 mm.
What protection and indication are included?
A Schneider 40A/1P circuit breaker provides protection and monitoring, and a hot-swap indicator lamp provides control indication.
Related products
-

GDE-100A1P-lgt-6C13+18C19-FT-B Rack PDU, AC220V 100A 1P, 6×C13 + 18×C19 Locking Outlets
Request a quote -

GDE-63A-lgt-20GB10A+4GB16A-FT-B Rack PDU, AC220V 63A, 20× GB10A + 4× GB16A Anti-Drop Outlets
Request a quote -

PDU-AC220V-32A-20GB10A+4GB16A Rack Power Distribution Unit, 20× GB10A + 4× GB16A Anti-Loosening Outlets
Request a quote -

PDU-AC220V-32A-GFM-D5-20C13+10C19-GDE-32A1P-lgt-20C13+10C19-FT Rack Power Distribution Unit — AC220V 32A, 20×C13 + 10×C19 Outlets
Request a quote




Reviews
There are no reviews yet.