GDV-20-385-1+1-FM AC Power Surge Protective Device, Class II, 1+1 Configuration with Remote Signaling
Request a quote
Quality & certifications
Description
The GDV-20-385-1+1-FM is a Class II AC power surge protective device (SPD) designed for lightning overvoltage protection of single-phase AC power supplies. It uses a 1+1 configuration to protect both the L-N and N-PE paths, with a nominal discharge current In of 10 kA and a maximum discharge current Imax of 20 kA.
Product Overview
The GDV-20-385-1+1-FM is an AC power surge protective device intended for Class II lightning overvoltage protection on single-phase AC supply systems. It provides protection between line and neutral (L-N) and between neutral and protective earth (N-PE). The device includes a visual status indicator and a remote signaling changeover contact for monitoring.
Key Features
- Class II surge protective device for single-phase AC power
- 1+1 configuration protecting both L-N and N-PE paths
- Nominal discharge current In: 10 kA
- Maximum discharge current Imax: 20 kA
- Voltage protection level Up: ≤1.2 kV (L-N), ≤0.8 kV (N-PE)
- Response time tA: 25 ns (L-N), 100 ns (N-PE)
- Visual status indication: green for normal, red for failure
- Remote signaling changeover contact
- 35 mm DIN rail mounting
- Housing material PC+ABS with UL94-V0 flame rating
- IP20 enclosure protection
Technical Specifications
| Parameter | Value |
|---|---|
| Model | GDV-20-385-1+1-FM |
| SPD classification | II |
| Nominal operating voltage Un | 220V~ |
| L-N maximum continuous AC operating voltage Uc | 385V~ |
| N-PE maximum continuous AC operating voltage Uc | 255V~ |
| Nominal discharge current In | 10kA |
| Maximum discharge current Imax | 20kA |
| L-N voltage protection level Up (In@8/20µs) | ≤1.2kV |
| N-PE voltage protection level Up (In@8/20µs) | ≤0.8kV |
| L-N response time tA | 25ns |
| N-PE response time tA | 100ns |
| L-N, N-PE status indication | Green: normal / Red: failure |
| Mounting method | 35mm DIN rail |
| Conductor connection capacity | ≤25mm² |
| Maximum torque | 3.2Nm~3.7Nm |
| Housing material | PC+ABS |
| Housing material flame rating | UL94-V0 |
| Remote signaling contact type | Changeover contact |
| Remote signaling contact AC performance | 250V/0.5A |
| Remote signaling contact DC performance | 125V/0.2A |
| Enclosure protection rating | IP20 |
| Temperature (humidity) range | -40℃ to +80℃, relative humidity ≤95% |
| Altitude | ≤3000m |
| Main body dimensions | 90mm×65.3mm×36mm (tolerance ±1 mm) |
Applications
The GDV-20-385-1+1-FM is used for Class II lightning overvoltage protection of single-phase AC power supplies. It is suitable for installation in AC power distribution systems where protection between L-N and N-PE is required.
Installation and Use
The device can be connected using the conventional direct parallel wiring or V-shaped wiring shown in the wiring diagram. For better protection with direct parallel wiring, keep the wiring as short as possible, with a total length within 0.5 m.
Use 4-16 mm² multi-core copper conductors for the connection. A suitable circuit breaker or fuse must be connected upstream of the device; the circuit breaker should have a C trip characteristic.
Disconnect the power supply before installation. Live operation is strictly prohibited. The connecting conductors must meet the requirements.
When the SPD is working normally, the status indicator window is green, the alarm dry contact NC-COM is conducting, and the alarm dry contact NO-COM is open. When the SPD fails, the status indicator turns red, the alarm dry contact NC-COM becomes open, and the alarm dry contact NO-COM becomes conducting.
The SPD requires no special maintenance. Periodically check whether the module is loose and whether the status indication is normal.
The SPD can be judged as failed and should be replaced promptly if either of the following occurs: the status indicator turns red, or the alarm dry contact becomes open.
Frequently Asked Questions
What is the difference between the L-N and N-PE protection levels?
The L-N voltage protection level Up is ≤1.2 kV, and the N-PE voltage protection level Up is ≤0.8 kV, both measured at In with an 8/20 µs waveform.
How do I know when the SPD has failed?
When the SPD fails, the status indicator changes from green to red, and the alarm dry contact NC-COM becomes open while NO-COM becomes conducting.
What conductor size should be used?
Use 4-16 mm² multi-core copper conductors for the connection.
Related products
-

GBC-25-255-4 Three-Phase AC Power Surge Protective Device, 25 kA Iimp, 255 V~ Uc
Request a quote -

GCV-40-385-3+1 AC Power Surge Protective Device, Class II, 3+1 Configuration
Request a quote -

GCV-40-385-3+1 FM Three-Phase AC Power Surge Protective Device, Class II, 40kA Imax
Request a quote -

G1V-40-385-FM Three-Phase AC Power Surge Protective Device, Class II, 40kA Imax, Hot-Swappable
Request a quote




Reviews
There are no reviews yet.