GDE-40A2P-Lgt-16GB10A+8GB16A-FT-B Rack PDU, AC220V 40A 2P Input, 16× GB10A + 8× GB16A Anti-Drop Outlets

Request a quote

Request a Quote

Description

The GDE-40A2P-Lgt-16GB10A+8GB16A-FT-B is a rack power distribution unit with a single-phase AC220V 40A input and a 2P configuration. It distributes power through 16 GB10A anti-drop outlets and 8 GB16A anti-drop outlets, a 16+8 outlet combination. The unit is built with copper busbar internal connections, an aluminum alloy housing, and a hot-swap indicator, and it is intended for vertical right bracket mounting on the rear side of a cabinet.

Product Overview

This PDU is identified by the model GDE-40A2P-Lgt-16GB10A+8GB16A-FT-B and product code 10300413. It accepts a single-phase input through a terminal box, with the cable entering from the top. The input can accept 3×10mm² conductors, and the cable is secured with a PG21 gland. Power is distributed to 16 GB10A anti-drop outlets and 8 GB16A anti-drop outlets.

The housing is made of aluminum alloy and finished in black RAL9005. The unit includes a hot-swap indicator for control indication and a circuit breaker for protection monitoring. The circuit breaker brand is Schneider, rated 40A/1P.

Key Features

  • Single-phase AC220V 40A input with 2P configuration
  • 16 GB10A anti-drop outlets plus 8 GB16A anti-drop outlets (16+8 combination)
  • Copper busbar internal connections, 3.0mm diameter
  • Top cable entry with PG21 cable fixing
  • Input conductor capacity of 3×10mm²
  • Aluminum alloy housing in black RAL9005
  • Hot-swap indicator for control indication
  • Schneider 40A/1P circuit breaker for protection monitoring
  • Bracket mounting, vertical right orientation for the rear side of a cabinet

Technical Specifications

Parameter Value
Model GDE-40A2P-Lgt-16GB10A+8GB16A-FT-B
Product code 10300413
Product type Power distribution unit
Input AC220V 40A, single-phase, 2P
Input connection Terminal box
Cable entry Top input
Input conductor capacity 3×10mm²
Cable fixing PG21
Outlet configuration 16 × GB10A anti-drop + 8 × GB16A anti-drop
Outlet combination 16+8
Internal connection Copper busbar, 3.0mm diameter
Circuit breaker Schneider 40A/1P
Control indication Hot-swap indicator
Protection monitoring Circuit breaker
Housing material Aluminum alloy
Housing color Black RAL9005
Dimensions (L×W×H) 1726×60×44mm
Dimension tolerance L ±4mm; W/H ±2mm
Mounting hole center distance 1694mm
Aluminum alloy housing length 1651mm
Installation method Bracket mounting
Installation orientation Vertical right mounting (rear side of cabinet)
Screw torque M3 0.6N.m / 6kgf.cm
Screw torque M4 1.6N.m / 16.3kgf.cm
Screw torque M5 3N.m / 30.5kgf.cm
Screw torque M6 5N.m / 51kgf.cm
Screw torque M8 11N.m / 112kgf.cm
Factory accessories M6×12 screws and M6 floating square nuts, 4 pcs each; manual including certificate of conformity, 1 pcs
Product identification input AC220V 40A
Product identification output 16 × GB10A + 8 × GB16A anti-drop
Silkscreen marking B1-01~B1-12 / B2-01~B2-12

Applications

The GDE-40A2P-Lgt-16GB10A+8GB16A-FT-B is intended for rack power distribution in cabinets, using bracket mounting in a vertical right orientation on the rear side of the cabinet. It provides a combination of GB10A and GB16A anti-drop outlets for equipment requiring those outlet types.

Installation and Use

Install the PDU using the bracket mounting method in a vertical right orientation on the rear side of the cabinet. The mounting hole center distance is 1694mm, and the aluminum alloy housing length is 1651mm. The cable enters from the top and is fixed with a PG21 gland; the input can accept 3×10mm² conductors.

Observe the specified screw torques during installation: M3 at 0.6N.m (6kgf.cm), M4 at 1.6N.m (16.3kgf.cm), M5 at 3N.m (30.5kgf.cm), M6 at 5N.m (51kgf.cm), and M8 at 11N.m (112kgf.cm). The factory accessories include M6×12 screws and M6 floating square nuts, 4 pcs each, plus a manual including a certificate of conformity, 1 pcs.

Frequently Asked Questions

What is the input rating of this PDU?

The input is AC220V 40A, single-phase, with a 2P configuration and a terminal box input connection.

How many outlets does the PDU provide?

It provides 16 GB10A anti-drop outlets and 8 GB16A anti-drop outlets, for a 16+8 combination.

What circuit breaker is used?

The circuit breaker is a Schneider 40A/1P device.

How is the unit mounted?

It is bracket mounted in a vertical right orientation on the rear side of the cabinet, with a mounting hole center distance of 1694mm.