GCV-60-385-3+1 AC Power Surge Protective Device, 60kA Imax, 3+1 Configuration

Request a quote

Request a Quote

Description

The GCV-60-385-3+1 is a Class II (C-level) surge protective device for AC power systems, intended for the second stage of protection at load equipment. It is a 3+1 configuration device rated for a 385V maximum continuous operating voltage and a 60kA maximum discharge current (8/20μs).

Product Overview

The GCV-60 series surge protective device is used for second-stage (Class C) lightning and surge protection of load equipment in power systems. The GCV-60-385-3+1 variant uses a 3+1 pole configuration. The device is designed to be installed in LPZ1 zones or directly inside distribution cabinets (switch boxes).

Key Features

  • Class II (C-level) surge protection for AC power systems
  • 3+1 configuration
  • Maximum continuous operating voltage Uc: 385V
  • Nominal discharge current In (8/20μs): 30kA
  • Maximum discharge current Imax (8/20μs): 60kA
  • Voltage protection level Up (at In): 2.0kV
  • N-PE maximum continuous operating voltage Uc: 255V
  • N-PE voltage protection level Up (at In): 1.0kV
  • Status indicator: green for normal, red for failed
  • 35mm DIN rail mounting
  • IP20 enclosure rating

Technical Specifications

Parameter Value
Model GCV-60/385/3+1
Maximum continuous operating voltage Uc 385V
Nominal discharge current In (8/20μs) 30kA
Maximum discharge current Imax (8/20μs) 60kA
Voltage protection level Up (at In) 2.0kV
N-PE maximum continuous operating voltage Uc 255V
N-PE voltage protection level Up (at In) 1.0kV
Failure indication Green: normal; Red: failed
Backup fuse 32Agl/gG
Temperature range -40℃…+80℃
Installation wiring method / specification Parallel / stranded 10-35mm²
Housing material Reinforced thermoplastic, UL94-V0
Product dimensions 91*65.5*72 mm
Mounting method 35mm DIN rail
Protection rating IP20

Applications

The GCV-60-385-3+1 is used for second-stage (Class C) lightning and surge protection of load equipment in AC power systems. It can be installed in LPZ1 zones or directly in distribution cabinets (switch boxes).

Installation and Use

  • The device can be installed in LPZ1 zones or directly in distribution cabinets (switch boxes).
  • It can be fixed on a 35mm electrical DIN rail.
  • The device is connected in parallel to the power line. “L/+” connects to the phase line or positive line; “N/-” connects to the neutral line or negative line. The copper conductor cross-section at both ends of the device is 10-35mm².
  • An overcurrent protection device such as an air switch or fuse must be installed ahead of the SPD in the circuit.
  • The grounding connection should use the shortest possible wire. The device uses terminal grounding; the grounding wire must be connected to the lightning protection ground.
  • The protected line should maintain sufficient safety distance from the incoming line and ground line to avoid secondary induction.
  • Under conditions not exceeding the specified requirements, the device does not require long-term maintenance, only routine system maintenance. If the green indicator window turns red during use, the device is damaged and must be repaired or replaced.

Frequently Asked Questions

What does the status indicator mean?

A green window indicates normal operation. A red window indicates the device has failed and needs repair or replacement.

What is the maximum discharge current of the GCV-60-385-3+1?

The maximum discharge current Imax is 60kA (8/20μs).

What backup fuse is specified?

A 32Agl/gG backup fuse is specified.

What is the operating temperature range?

The temperature range is -40℃ to +80℃.