GDE-32A-lgt-20GB10A+4GB16A-FT-A Rack PDU — 32A Input, 20× GB10A + 4× GB16A Anti-Loose Outlets
Request a quote
Description
The GDE-32A-lgt-20GB10A+4GB16A-FT-A is a rack power distribution unit rated for an AC220V 32A input. It distributes power to 24 outlets arranged as 20 GB10A anti-loose sockets and 4 GB16A anti-loose sockets. The unit uses copper busbar internal connections with a diameter of 2.5 mm and is enclosed in a black RAL9005 aluminum alloy housing.
Product Overview
This PDU is configured for top-entry cable connection through a terminal box with a transparent cover. The input end accepts 3×6 mm² conductors, and the cable is fixed with a PG19 gland. The enclosure measures 1579 × 60 × 44 mm (L × W × H), with a mounting hole center distance of 1539 mm and an aluminum alloy housing length of 1479 mm. It is installed vertically on the left side of the cabinet rear using brackets.
Key Features
- 24 outlets: 20 GB10A anti-loose sockets and 4 GB16A anti-loose sockets
- AC220V 32A input rating
- Copper busbar internal connections, 2.5 mm diameter
- Terminal box with transparent cover for top-entry input
- PG19 cable fixing
- Hot-swap indicator light for control indication
- Black RAL9005 aluminum alloy enclosure
- Vertical left-side mounting on the cabinet rear
Technical Specifications
| Parameter | Value |
|---|---|
| Product code | 10300333 |
| Product model | GDE-32A-lgt-20GB10A+4GB16A-FT-A |
| Customer product model | ZXSPDU 32A-20GB10A+4GB16A(A) |
| Product code (internal) | 051601501209 |
| Warranty period | 3 years |
| Outlet type and quantity | 20 × GB10A anti-loose + 4 × GB16A anti-loose |
| Outlet combination | 20+4 |
| Internal connection | Copper busbar connection (diameter 2.5 mm) |
| Power input method | Terminal box (transparent cover) |
| Cable plug type | / |
| Input conductor capacity | 3×6 mm² |
| Cable installation method | Top entry |
| Cable fixing | PG19 |
| Enclosure color | Black RAL9005 |
| Dimensions (L×W×H) | 1579×60×44 mm; tolerance: L ±4 mm, W/H ±2 mm |
| Mounting hole center distance | 1539 mm |
| Aluminum alloy housing length | 1479 mm |
| Installation method | Bracket mounting |
| Bracket mounting direction | Vertical left mounting (rear of cabinet) |
| Control indication | Hot-swap indicator light |
| Protection monitoring | / |
| Screw torque | M3: 0.6 N·m / 6 kgf·cm; M4: 1.6 N·m / 16.3 kgf·cm; M5: 3 N·m / 30.5 kgf·cm; M6: 5 N·m / 51 kgf·cm; M8: 11 N·m / 112 kgf·cm (torque tolerance ±10%) |
| Factory accessories | M6×12 screws and M6 floating square nuts, 4 pcs each; manual (including certificate of conformity) 1 pcs |
| Product identification — input | AC220V 32A |
| Product identification — output | 20 × GB10A + 4 × GB16A anti-loose |
Applications
The GDE-32A-lgt-20GB10A+4GB16A-FT-A is intended for rack power distribution in cabinets, where it provides 20 GB10A and 4 GB16A anti-loose outlets from a single AC220V 32A input. Its vertical left-side rear-cabinet mounting and top-entry cable connection suit rack installations that require a high outlet count in a narrow enclosure.
Installation and Use
Install the PDU vertically on the left side of the cabinet rear using the supplied brackets. Route the input cable to the top-entry terminal box with transparent cover and secure it with the PG19 cable fixing. The input end accepts 3×6 mm² conductors. Use the specified screw torque values during installation: M3 at 0.6 N·m (6 kgf·cm), M4 at 1.6 N·m (16.3 kgf·cm), M5 at 3 N·m (30.5 kgf·cm), M6 at 5 N·m (51 kgf·cm), and M8 at 11 N·m (112 kgf·cm), with a torque tolerance of ±10%. The hot-swap indicator light provides control indication. Factory accessories include M6×12 screws and M6 floating square nuts, 4 pcs each, plus one manual containing the certificate of conformity.
Frequently Asked Questions
What is the input rating of this PDU?
The input rating is AC220V 32A, as marked on the product identification label.
How many outlets does the PDU provide?
It provides 24 outlets in total: 20 GB10A anti-loose sockets and 4 GB16A anti-loose sockets.
How is the PDU mounted?
It is bracket-mounted vertically on the left side of the cabinet rear.
What cable size can the input accept?
The input end can connect 3×6 mm² conductors, with top entry and PG19 cable fixing.
Related products
-

PDU-AC220V-40A2P-16GB10A+8GB16A Rack Power Distribution Unit, 16× GB10A + 8× GB16A Anti-Loosening Outlets, Single-Phase 40A
Request a quote -

PDU-AC220V-32A-20C13+4C19 Rack Power Distribution Unit — 20×C13 + 4×C19, Vertical Left Mount
Request a quote -

GDE-40A2P-Lgt-16GB10A+8GB16A-FT-B Rack PDU, AC220V 40A 2P Input, 16× GB10A + 8× GB16A Anti-Drop Outlets
Request a quote -

GDE-63A-lgt-20GB10A+4GB16A-FT-B Rack PDU, AC220V 63A, 20× GB10A + 4× GB16A Anti-Drop Outlets
Request a quote



Reviews
There are no reviews yet.