PDU-DC240V-63A2P-F-10GB16A-GDZ-GDZ-63A2P-lgt-10GB16A-FT DC 240V 63A 2P Rack PDU with 10 GB16A Locking Outlets and SPD

Request a quote

Request a Quote

Description

The GDZ-63A2P-lgt-10GB16A-FT is a DC 240V rack power distribution unit rated 63A with a 2-pole circuit breaker. It distributes power to ten GB16A locking outlets in a 10+0 configuration and is intended for horizontal, bracket-mounted installation in equipment racks.

Product Overview

This PDU accepts a DC 240V 63A input through a terminal box with a transparent cover. Input conductors are connected on the left side and secured with a PG25 cable gland. Internal connections use copper busbars of 3.6 mm diameter. The front panel carries a hot-swap indicator lamp, and the unit includes a Schneider 63A 2P circuit breaker together with surge protection monitoring.

Key Features

  • DC 240V, 63A input with a 2-pole circuit breaker
  • Ten GB16A locking outlets in a 10+0 configuration
  • Schneider 63A 2P circuit breaker
  • Surge protection monitoring: Uc 275VDC, In 10kA, Imax 20kA, Up (10kA) 1.2kV
  • Hot-swap indicator lamp
  • Copper busbar internal connections, 3.6 mm diameter
  • Left-side cable entry with PG25 cable fixing
  • Black RAL9005 sheet-metal enclosure
  • Horizontal bracket mounting

Technical Specifications

Parameter Value
Product code 10300362
Product model GDZ-63A2P-lgt-10GB16A-FT
Customer product model PDU-DC240V-63A2P-F-10GB16A-GDZ
Product code (internal) 051601501255
Input DC240V 63A
Circuit breaker Schneider 63A 2P
Outlet type and quantity 10 × GB16A locking
Outlet combination 10+0
Internal connection Copper busbar, 3.6 mm diameter
Power input method Terminal box (transparent cover)
Cable plug type —
Input conductor capacity 3 × 16 mm²
Cable installation Left-side input
Cable fixing PG25
Enclosure color Black RAL9005
Dimensions (L × W × H) 482.6 × 100 × 45 mm; tolerance: L ± 4 mm, W/H ± 2 mm
Mounting hole center distance 465.1 mm
Sheet-metal enclosure length —
Installation method Bracket mounting
Bracket mounting direction Horizontal
Control and indication Hot-swap indicator lamp; circuit breaker + SPD
Protection monitoring Uc: 275VDC; In: 10kA; Imax: 20kA; Up (10kA): 1.2kV
Screw torque M3: 0.6 N·m / 6 kgf·cm; M4: 1.6 N·m / 16.3 kgf·cm; M5: 3 N·m / 30.5 kgf·cm; M6: 5 N·m / 51 kgf·cm; M8: 11 N·m / 112 kgf·cm (tolerance ±10%)
Factory accessories M6×12 screws and M6 floating square nuts, 4 pcs each; manual (including certificate of conformity), 1 pc
Warranty period 3 years

Applications

The unit is designed for DC 240V power distribution in rack-mounted equipment, using ten GB16A locking outlets to supply connected loads. Horizontal bracket mounting and a 465.1 mm mounting hole center distance suit standard rack installation.

Installation and Use

Install the PDU horizontally using the supplied brackets. Route input conductors to the left-side terminal box and secure the cable with the PG25 gland. The terminal box accepts conductors up to 3 × 16 mm². Tighten screws to the specified torque values: M3 at 0.6 N·m, M4 at 1.6 N·m, M5 at 3 N·m, M6 at 5 N·m, and M8 at 11 N·m, each within ±10%. The transparent terminal cover allows visual inspection of connections. The hot-swap indicator lamp shows outlet status, and the circuit breaker with SPD provides protection monitoring.

Frequently Asked Questions

What input does this PDU accept?

It accepts a DC 240V, 63A input through a left-side terminal box with a transparent cover.

How many outlets does it provide?

It provides ten GB16A locking outlets in a 10+0 configuration.

What surge protection values are specified?

The protection monitoring values are Uc: 275VDC, In: 10kA, Imax: 20kA, and Up (10kA): 1.2kV.

What is included with the unit?

Factory accessories include M6×12 screws and M6 floating square nuts (4 pcs each) and a manual with certificate of conformity.